Siemens SINAMICS S Series - p3738[0...n] APC filter 3.2 numerator natural frequency; APC Filt 3.2 fn_n; p3739[0...n] APC filter 3.2 numerator damping; APC Filt 3.2 D_n; p3760[0...n] APC load speed controller 1 P gain; APC n_load ctr1 Kp; p3760[0...n] APC load velocity controller 1 P gain; APC v_load ctr1 Kp

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-739
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: p3704, p3705
Description: Sets the numerator natural frequency for filter 3.2 (general 2nd Order filter) for APC (Advanced Positioning Control).
Dependency: Refer to: p3704, p3705
Description: Sets the numerator damping for filter 3.2 (general 2nd Order filter) for APC (Advanced Positioning Control).
Dependency: Refer to: p3704, p3705
Description: Sets the proportional gain of the load speed controller 1 for APC (Advanced Positioning Control).
The gain acts on the difference between the speed setpoint and load speed in the branch for filter 2.1 and 2.2.
Description: Sets the proportional gain of the load velocity controller 1 for APC (Advanced Positioning Control).
The gain acts on the difference between the velocity setpoint and load velocity in the branch for filter 2.1 and 2.2.
Description: Sets the rate time of the load speed controller 1 for APC (Advanced Positioning Control).
The rate time acts on the load acceleration in the branch for filter 2.1 and 2.2.
p3738[0...n] APC filter 3.2 numerator natural frequency / APC Filt 3.2 fn_n
SERVO (APC) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7012
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 2000.0 [Hz]
p3739[0...n] APC filter 3.2 numerator damping / APC Filt 3.2 D_n
SERVO (APC) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7012
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.000 10.000 0.700
p3760[0...n] APC load speed controller 1 P gain / APC n_load ctr1 Kp
SERVO (APC) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7012
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
-100.000 100.000 0.000
p3760[0...n] APC load velocity controller 1 P gain / APC v_load ctr1 Kp
SERVO (APC, Lin) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7012
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
-100.000 100.000 0.000
p3761[0...n] APC load speed controller 1 rate time / APC n_load ctr1 Tv
SERVO (APC) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7012
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
-500.00 [ms] 500.00 [ms] 0.00 [ms]