Siemens SINAMICS S Series - p0820[0...n] BI: Drive data set selection DDS bit 0; DDS select., bit 0; p0821[0...n] BI: Drive data set selection DDS bit 1; DDS select., bit 1; p0822[0...n] BI: Drive data set selection DDS bit 2; DDS select., bit 2; p0823[0...n] BI: Drive data set selection DDS bit 3; DDS select., bit 3

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-242
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source to select the Drive Data Set, bit 0 (DDS, bit 0).
Dependency: Refer to: r0051, r0837
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source to select the Drive Data Set, bit 1 (DDS, bit 1).
Dependency: Refer to: r0051, r0837
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source to select the Drive Data Set, bit 2 (DDS, bit 2).
Dependency: Refer to: r0051, r0837
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source to select the Drive Data Set, bit 3 (DDS, bit 3).
Dependency: Refer to: r0051, r0837
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p0820[0...n] BI: Drive data set selection DDS bit 0 / DDS select., bit 0
SERVO, TM41, VEC-
TOR
Can be changed: C2(15), T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: 8565
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p0821[0...n] BI: Drive data set selection DDS bit 1 / DDS select., bit 1
SERVO, TM41, VEC-
TOR
Can be changed: C2(15), T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: 8565
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p0822[0...n] BI: Drive data set selection DDS bit 2 / DDS select., bit 2
SERVO, TM41, VEC-
TOR
Can be changed: C2(15), T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: 8565
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p0823[0...n] BI: Drive data set selection DDS bit 3 / DDS select., bit 3
SERVO, TM41, VEC-
TOR
Can be changed: C2(15), T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: 8565
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0