Description: Displays the motor stator resistance at an ambient temperature p0625. The value does not include the cable resis-
tance.
Dependency: Refer to: p0625
Description: Displays the cable resistance between the Motor Module and motor.
Dependency: Refer to: p0352
Description: Displays the rated motor stator resistance at rated temperature (sum from p0625 and p0627).
Dependency: Refer to: p0627
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the rotor/secondary section resistance of the motor for the ambient temperature p0625.
For separately-excited synchronous motors: Displays the damping resistance in the rotor direction (d-axis).
Dependency: Refer to: p0625
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
r0370[0...n] Motor stator resistance, cold / Mot R_stator cold
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Ohm] - [Ohm] - [Ohm]
r0372[0...n] Cable resistance / Mot R_cable
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Ohm] - [Ohm] - [Ohm]
r0373[0...n] Motor rated stator resistance / Mot R_stator rated
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
- [Ohm] - [Ohm] - [Ohm]
r0374[0...n] Motor rotor resistance cold / damping resistance d axis / Mot R_r cold / RDd
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL Expert list: 1
Min Max Factory setting
- [Ohm] - [Ohm] - [Ohm]