List of parameters
Parameters
1-663
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source for the feedback signal "torque limit reached" when traversing to fixed stop.
BI: p2639 = 1 signal
Torque limit is reached.
BI: p2639 = 0 signal
Torque limit is not reached.
Dependency: Refer to: r1407
Note: The feedback signal from "torque limit reached" is, for the factory setting, dependent on the signal BO: r1407.7
(torque limit reached).
Description: Sets the signal source for the "no intermediate stop/intermediate stop".
BI: p2640 = 1 signal
No intermediate stop.
BI: p2640 = 0 signal
Intermediate stop.
Dependency: Refer to: p2631, p2641, p2647, p2649
Caution: For BI: p2649 = 1 signal, the following applies:
Motion starts without any explicit control signal.
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: This signal is only effective in the modes "traversing blocks" and "direct setpoint input/MDI".
When activating the intermediate stop, the axis brakes with the parameterized deceleration (p2620 or p2645).
Description: Sets the signal source for "do not reject traversing task/reject traversing task".
BI: p2641 = 1 signal
Do not reject traversing task.
BI: p2641 = 0 signal
Reject traversing task.
Dependency: Refer to: p2631, p2640, p2647, p2649
Caution: For BI: p2649 = 1 signal, the following applies:
Motion starts without any explicit control signal.
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2639 BI: EPOS torque limit reached / M_limit reached
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3616
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 1407.7
p2640 BI: EPOS intermediate stop (0 signal) / Intermediate stop
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3616, 3625
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2641 BI: EPOS reject traversing task (0 signal) / Trav_task reject
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3616, 3625
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0