EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-6 1510 - CU320 input;output terminals

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Overviews
2-1108
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-6 1510 – CU320 input/output terminals
- 1510 -
Function diagram
87654321
fp_1510_51_eng.vsd
DO: CU_GL, CU_GM, CU_S
SINAMICS
08.03.07 V02.05.00
Overviews - CU320 input/output terminals
=
~
+ 24 V
+
M
M
M
DI 0
X122
DI 1
DI 3
DI 2
M 1
M
DI/DO 8
DI/DO 9
DI/DO 10
DI/DO 11
M
M
4
3
2
1
5
6
7
8
9
10
11
12
1
r0722.0 r0723.0
1
r0722.3 r0723.3
1
0
1
0
p0738
1
r0722.8 r0723.8
p0728.8
p0728.11
p0741
1
r0722.11 r0723.11
4 digital inputs, electrically isolated
4 digital inputs/outputs, bidirectional
[2131]
DI 4
X132
DI 5
DI 7
DI 6
M 2
M
DI/DO 12
DI/DO 13
DI/DO 14
DI/DO 15
M
M
4
3
2
1
5
6
7
8
9
10
11
12
...
...
...
...
...
...
1
r0722.4 r0723.4
1
r0722.7 r0723.7
1
0
1
0
p0742
1
r0722.12 r0723.12
p0728.12
p0728.15
p0745
1
r0722.15 r0723.15
4 digital inputs, electrically isolated
[2132]
[2133]
...
...
...
...
...
...
+24 V DC to the
next device
X124
M
M
+
+
...
...
<1>
<1>
<1>
<1>
<1>
<1>
<2>
<2>
CU320
<1> For SERVO and VECTOR, the following applies:
Fast measuring probe inputs.
<2> Jumper open, electrical isolation for DI 0...3 and DI 4...7
Simulation for DI 0...DI 15
1
0
1 = Simulation on
p0795.0...15
Simulation signals
p0796.0...15
r0722.0...15
r0721.0...15
1
r0723.0...15
4 digital inputs/outputs, bidirectional
[2121]
[2130]
[2120]
p0799 (4000.00 µs)

Table of Contents

Related product manuals