EasyManua.ls Logo

Siemens SINAMICS S Series - r0047 Status, identification; Status ident

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-61
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the currently executed steps or the first step after the enable for the motor identification and pole position
identification routines.
Values: 0: No measurement
1: PolID: Wait for brake closing time
2: PolID: Measurement, step 1
3: PolID: Measurement, step 2
4: PolID: Measurement, step 3
5: PolID: Measurement, step 4
6: PolID: Measurement, stage 2
7: PolID: Measurement evaluation
8: PolID: Measurement end
11: MotID: Inductance measurement, step 1
12: MotID: Inductance measurement, step 2
13: MotID: Inductance measurement evaluation
14: MotID: Resistance measurement evaluation
15: MotID: Fine synchronization, step 1
16: MotID: Fine synchronization, step 2
17: MotID: Fine synchronization, step 3
18: MotID: Fine synchronization, end
20: MotID: Rotating inductance measurement, step 1
21: MotID: Rotating inductance measurement, step 2
22: MotID: Rotating inductance measurement, step 3
23: MotID: Rotating inductance measurement, step 4
24: MotID: Rotating Inductance measurement evaluation
25: MotID: Rotating Inductance measurement end
30: MotID: Induction motor measurement, step 1
31: MotID: Induction motor measurement, step 2
32: MotID: Induction motor measurement, step 3
33: MotID: Induction motor measurement, step 4
34: MotID: Induction motor measurement, step 5
35: MotID: Induction motor measurement, step 6
36: MotID: Induction motor measurement, step 7
37: MotID: Induction motor measurement, step 8
38: MotID: Induction motor measurement, step 9
40: MotID: Commutating angle, step 1
41: MotID: Commutating angle, step 2
42: MotID: Commutating angle, step 3
43: MotID: Commutating angle, step 4
45: MotID: Commutating angle rotating, step 1
46: MotID: Commutating angle rotating, step 2
47: MotID: Commutating angle rotating, step 3
48: MotID: Commutating angle rotating complete
50: MotID: kT determination, step 1
51: MotID: kT determination, step 2
52: MotID: kT determination, step 3
53: MotID: kT determination evaluation
54: MotID: kT determination end
60: MotID: Reluctance constant measurement, step 1
61: MotID: Reluctance motor measurement, step 2
62: MotID: Reluctance constant measurement, step 3
63: MotID: Reluctance constant measurement end
70: MotID: Moment of inertia measurement, step 1
71: MotID: Moment of inertia measurement, step 2
r0047 Status, identification / Status ident
SERVO Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 104 -

Table of Contents

Related product manuals