Parameters
List of parameters
1-498
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the nominal stator inductance identified.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays the nominal stator inductance identified for the 1st point of the saturation characteristic.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays the nominal stator inductance identified for the 2nd point of the saturation characteristic.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays the nominal stator inductance identified for the 3rd point of the saturation characteristic.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
r1915[0...2] Identified nominal stator inductance / L_stator ident
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r1916[0...2] Identified stator inductance 1 / L_stator 1 ident
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r1917[0...2] Identified stator inductance 2 / L_stator 2 ident
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r1918[0...2] Identified stator inductance 3 / L_stator 3 ident
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S Series and is the answer not in the manual?

Siemens SINAMICS S Series Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals