Parameters
List of parameters
1-764
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Re bit 00 = 1:
The encoder is parked. Contrary to r0481.14, parking is also displayed here if the suppression of the parking bit is
active in r0481.14 (p3870.1 = 1).
Re bit 01 = 1:
The long-stator functions requested closed-loop velocity control with encoder. In r1407.2, it is indicated as to
whether an encoder is actually used for the closed-loop control.
Description: Sets the signal source 1 to unpark the encoder.
Dependency: Refer to: p3870, p3871, p3872, p3873, p3874, r3875, p3878, p3879
Note: BI: p3876 = 1 signal --> encoder is unparked
BI: p3876 = 0 signal --> encoder is parked
Description: Enters the commutation angle 1 for long stator motors.
Dependency: Refer to: p3870, p3871, p3872, p3873, p3874, r3875, p3876, p3879
Description: Enters the commutation angle 2 for long stator motors.
Dependency: Refer to: p3870, p3871, p3872, p3873, p3874, r3875, p3876, p3878
Description: Exits the quick commissioning (p0010 = 1) with automatic calculation of all of the parameters that depend on the
entries made during the quick commissioning.
p3900 = 1 initially includes a parameter reset (factory setting, the same as p0970 = 1) for all parameters of the drive
object; however, without overwriting the entries made during the quick commissioning. The interconnections of
PROFIBUS PZD telegram selection (p0922) and the interconnections via p0700 are re-established and all of the
dependent filter and closed-loop control parameters are calculated (corresponding to p0340 = 1).
p3876 BI: Unpark long stator signal source 1 encoder / S_src 1 enc unpark
SERVO Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p3878 CO: Long stator commutation angle 1 / Com_angle 1
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
-180 [°] 180 [°] 0 [°]
p3879 CO: Long stator commutation angle 2 / Com_angle 2
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
-180 [°] 180 [°] 0 [°]
p3900 Completion of quick commissioning / Compl quick_comm
A_INF, B_INF,
S_INF
Can be changed: C2(1) Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 3 0