Description: Displays the time when detecting the 1st and 2nd edge for digital input 1 of terminal module 17 (TM17).
The two times are specified as 16 bit values with a resolution of 0.25 µs.
Note: DI: Digital input
Description: Displays the time when detecting the 1st and 2nd edge for digital input 1 of terminal module 15 (TM15).
The two times are specified as 8 bit values with a resolution of 64 µs.
Note: DI: Digital input
Description: Displays the time when detecting the 1st and 2nd edge for digital input 2 of terminal module 17 (TM17).
The two times are specified as 16 bit values with a resolution of 0.25 µs.
Note: DI: Digital input
Description: Displays the time when detecting the 1st and 2nd edge for digital input 2 of terminal module 15 (TM15).
The two times are specified as 8 bit values with a resolution of 64 µs.
Note: DI: Digital input
r4351 TM17 edge times digital input 1 / TM17 edge_t DI 1
TM17 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4351 TM15 edge times digital input 1 / TM15 edge_t DI 1
TM15 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4352 TM17 edge times digital input 2 / TM17 edge_t DI 2
TM17 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4352 TM15 edge times digital input 2 / TM15 edge_t DI 2
TM15 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -