Parameters
List of parameters
1-1052
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the actual Node Identifier (word 3, bit 64 ... 95) for the Motor Modules.
Index: [0] = Drive 1
[1] = Drive 2
[2] = Drive 3
[3] = Drive 4
[4] = Drive 5
[5] = Drive 6
Dependency: Refer to: p10012, p10013
Note: The complete Node Identifier (96 bit) is represented in p10012, p10013 and p10014.
Description: Sets the special operating mode for the operating mode "function interface".
0 = Inactive
1 = Safe Operating Stop with braking (SS2)
2 = Safe Operating Stop without braking (SOS)
3 = Safely reduced speed without standstill (SLS)
4 = Safely reduced speed with agreement (SS2 --> SLS)
Index: [0] = Drive group 1
[1] = Drive group 2
[2] = Drive group 3
[3] = Drive group 4
Dependency: Refer to: p10008
Note: Parameter is being prepared - for this firmware version, the function interface is not supported.
SS2: Safe Stop 2
SOS: Safe Operating Stop
SLS: Safely-Limited Speed
Description: Sets the stop response for the drive group for Emergency Stop.
The input terminal for Emergency Stop is set in p10038.
0 = Stop reaction STO
1 = Stop reaction SS1
2 = Stop reaction SS2
p10014[0...5] SI Motor Module Node Identifier Word 3 / SI MM Node ID 3
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
p10020[0...3] SI special operating mode selection / SI spec op sel
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 3 1
p10021[0...3] SI Emergency Stop stop response / SI Emergency Stop
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 2 0