Parameters
List of parameters
1-862
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Values: 0: Measurement function inactive
1: Measuring function, parameterization checked
2: Measuring function waits for stabilizing time
3: Measuring function recording (tracing)
4: Measuring function, trace ended with error
5: Measuring function, trace successfully completed
Description: Displays the required memory in bytes for the actual parameterization.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Refer to: r4799
Description: Sets the trigger condition for the trace.
Values: 1: Immediate start
2: Positive edge
3: Negative edge
4: Entry to hysteresis band
5: Leaving hysteresis band
6: Trigger at bit mask
7: Start with function generator
Index: [0] = Trace 0
[1] = Trace 1
Description: Selects the trigger signal for the trace.
OR: Defines the data type of signal to be traced when selected using the physical address (p4789).
r4706 Measuring function, status / Meas fct status
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
0 5 -
r4708[0...1] Trace memory space required / Trace mem required
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -
p4710[0...1] Trace trigger condition / Trace Trig_cond
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
1 7 2
p4711[0...1] Trace trigger signal / Trace trig_signal
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - 0