Parameters
List of parameters
1-504
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
[10] = Force constant identification current
[11] = Force characteristic identification current measuring point 1
[12] = Force characteristic identification current measuring point 2
[13] = Force characteristic identification current measuring point 3
[14] = Force characteristic identification current measuring point 4
[15] = Force characteristic identification current measuring point 5
[16] = Force characteristic identification current measuring point 6
[17] = Force characteristic identification current measuring point 7
[18] = Force characteristic identification current measuring point 8
[19] = Force characteristic identification current measuring point 9
[20] = Force characteristic identification current measuring point 10
Dependency: Refer to: p1909, p1910, r1934, p1959, p1960
Note: - the Lq characteristic consists of the value pairs from r1934 and r1935 with the same index.
- the force constant is identified with the current r1935[10] and displayed in r1937[0]. If the reluctance force constant
is identified (p1959.7 = 1), the force constant is identified with 150% rated current (p0305), otherwise with 100%
rated current.
- the force characteristic (r1937[1...10]) is identified in the range between the rated current (p0305) and the maxi-
mum current (p0640) (r1935[11...20]).
Description: Displays the identification current to identify the q inductance ([0...9]).
Dependency: Refer to: r1934, p1959, p1960
Note: The Lq characteristic consists of the value pairs from r1934 and r1935 with the same index.
Description: Displays the identified magnetizing inductance(gamma equivalent circuit diagram).
Dependency: Refer to: p1909, p1910, r1913, r1915, r1927, p1959, p1960, r1962, r1963
Note: This value corresponds to the value of the transformed magnetizing inductance (r0382).
Description: Displays the identified torque constant/torque characteristic over the q current.
Index: [0] = Torque constant identified
[1] = Torque characteristic identified measuring point 1
[2] = Torque characteristic identified measuring point 2
[3] = Torque characteristic identified measuring point 3
[4] = Torque characteristic identified measuring point 4
[5] = Torque characteristic identified measuring point 5
r1935[0...9] q inductance identification current / Lq I_ident
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1936 Magnetizing inductance identified / L_H ident
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r1937[0...10] Torque constant identified / kT ident
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: 28_1 Unit selection: p0100
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Nm/A] - [Nm/A] - [Nm/A]