Dependency: Refer to: p7828
Note: Reference firmware version: Version on the CompactFlash card.
Actual firmware version: Actual version of the DRIVE-CLiQ component.
Description: Sets the behavior for the automatic firmware update of the DRIVE-CLiQ components.
Values: 0: De-activated
1: Upgrade and downgrade
2: Upgrade
Notice: If this parameter is changed, it only becomes effective the next time that the drive system boots.
Note: The firmware is automatically updated when the system boots. The boot can take several minutes.
After the update has been completed, it is necessary to carry out a new POWER ON (power-down/power-up) for
the components involved.
The firmware update procedure is displayed as follows:
Control Unit (LED RDY):
Flashes yellow with 0.5 Hz --> firmware is being updated.
Flashing yellow with 2 Hz --> POWER ON is required for the components involved.
Components involved:
Flashing red/green with 0.5 Hz --> firmware is being updated.
Flashing red/green with 2 Hz --> POWER ON of the components is required.
Only components from firmware version 2.5 support the red/green flashing at 2 Hz.
Description: Displays the progress when updating the firmware of the DRIVE-CLiQ components.
Description: Sets the component number for the required DRIVE-CLiQ component.
Index 0:
Component number of the DRIVE-CLiQ component for which a firmware download is to be made.
Index 1:
Component number of the DRIVE-CLiQ component to which the reference firmware version of the CompactFlash
card saved in r7825 is to be displayed.
Index: [0] = Firmware download
[1] = Reference firmware version
p7826 Firmware update automatic / FW update auto
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 2 1
r7827 Firmware update progress display / FW update progress
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
p7828[0...1] Firmware download component number / FW download number
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 399 0