Siemens SINAMICS S Series - r9408[0...19] PS file fault code parameter not transferred; PS fault code; r9409 Number of parameters to be saved; Qty par to save; r9450[0...29] Displays para. that cannot be calc. after int. ref. value change; Diag int ref chng; r9451[0...29] Units changeover adapted parameters; Unit_chngov par

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-988
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Only for internal Siemens service.
Dependency: Refer to: r9406, r9407
Note: All indices from r9406 to r9408 designate the same parameter.
r9406[x] parameter number, parameter not accepted
r9407[x] parameter index, parameter not accepted
r9408[x] fault code, parameter not accepted
Description: Displays the number of modified parameters and those that have still not be saved for this drive object.
Dependency: Refer to: p0971, p0977
Note: The modified parameters that still need to be saved are internally listed in r9410 ... r9419.
Description: Displays the parameters for which the re-calculation was unsuccesful after an internal system reference value
change.
Dependency: Refer to: F07086
Description: Displays the parameters whose parameter would have to be changed during a units changeover.
Dependency: Refer to: F07088
r9408[0...19] PS file fault code parameter not transferred / PS fault code
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, DMC20,
SERVO, S_INF,
TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41, VEC-
TOR
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r9409 Number of parameters to be saved / Qty par to save
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, DMC20,
SERVO, S_INF,
TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41, VEC-
TOR
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r9450[0...29] Displays para. that cannot be calc. after int. ref. value change / Diag int ref chng
A_INF, B_INF,
SERVO, S_INF,
TM41, VECTOR
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r9451[0...29] Units changeover adapted parameters / Unit_chngov par
A_INF, B_INF,
SERVO, S_INF,
TM41, VECTOR
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -