List of parameters
Parameters
1-655
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: p2595, p2597, p2604, p2607, p2608, p2610
Refer to: F07459
Description: Sets the tolerance bandwidth for the distance to the zero mark
The zero mark is evaluated within the maximum distance between the reference cam and zero mark (p2609) minus
the tolerance bandwidth for the distance to the zero mark (p2610).
Dependency: Refer to: p2609
Description: Sets the approach velocity after detecting the zero mark to approach the reference point.
Dependency: Refer to: p2595, p2597, p2604, p2607, p2609, p2610
Note: When traversing to the reference point, the velocity override is not effective.
Description: Sets the signal source for the reference cam.
Dependency: Refer to: p2607
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency: Refer to: p2614
Note: If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
p2610 EPOS search for ref., tol. bandwidth for distance to zero mark / Tol_band to ZM
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 3612
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [LU] 2147482647 [LU] 2147482647 [LU]
p2611 EPOS search for reference, approach velocity, reference point / v_appr ref_pt
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 3612
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1 [1000 LU/min] 40000000 [1000 LU/min] 300 [1000 LU/min]
p2612 BI: EPOS search for reference, reference cam / Ref_cam
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3612
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2613 BI: EPOS search for reference reversing cam minus / Rev minus
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3612
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 1