List of parameters
Parameters
1-693
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: RTC: Real Time Clock
UTC: Universal Time Coordinates
The UTC time started, according to the definition on 01.01.1970 at 00:00:00 and is output in days and milliseconds.
Description: Setting the UTC time.
This means that the drive system is synchronized to the time specified by the time master. To start p3101[1] must
be written to followed by p3101[0]. After writing to p3101[0], the UTC time is accepted.
p3101[0]: Milliseconds
p3101[1]: Days
Description: Displays the actual UTC time in the drive system.
p3102[0]: Milliseconds
p3102[1]: Days
Description: Sets the synchronization source/technique.
Values: 0: PROFIBUS
1: PROFINET
2: PPI
3: PROFINET PTP
Description: Sets the signal source for the PING event to set the UTC time.
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p3101[0...1] RTC set UTC time / RTC set UTC
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
0 4294967295 0
r3102[0...1] RTC read UTC time / RTC read UTC
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p3103 RTC synchronization source / RTC sync_source
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 3 0
p3104 BI: RTC real time synchronization PING / RTC PING
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0