Siemens SINAMICS S Series - p0627[0...n] Motor overtemperature, stator winding; Mot T_over stator; p0628[0...n] Rotor winding overtemperature; Mot T_over rotor; r0630[0...n] Motor temperature model ambient temperature; MotTMod T_amb.; r0631[0...n] Motor temperature model, stator core temperature; MotTMod T_iron

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-215
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: For 1LA5 and 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
Refer to: p0625
Description: Defines the rated overtemperature of the stator winding referred to the ambient temperature.
Dependency: For 1LA5 and 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
Refer to: p0625
Description: Defines the rated overtemperature of the squirrel cage rotor referred to ambient temperature.
Dependency: For 1LA5 and 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
Refer to: p0625
Description: Displays the ambient temperature of the motor temperature model.
Description: Displays the stator core temperature of the motor temperature model.
Description: Displays the stator winding temperature of the motor temperature model.
p0627[0...n] Motor overtemperature, stator winding / Mot T_over stator
SERVO, VECTOR Can be changed: C2(3), U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_2 Unit selection: p0505
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
20 [K] 200 [K] 80 [K]
p0628[0...n] Rotor winding overtemperature / Mot T_over rotor
SERVO, VECTOR Can be changed: C2(3), U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_2 Unit selection: p0505
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
20 [K] 200 [K] 100 [K]
r0630[0...n] Motor temperature model ambient temperature / MotTMod T_amb.
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_1 Unit selection: p0505
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
r0631[0...n] Motor temperature model, stator core temperature / MotTMod T_iron
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_1 Unit selection: p0505
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
r0632[0...n] Motor temperature model, stator winding temperature / MotTMod T_copper
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_1 Unit selection: p0505
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]