Parameters
List of parameters
1-958
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the sampling time for the cyclic interface 2 (IF2).
Description: Connector output for interconnecting the PZD (setpoints) received via interface 2 in the word format.
p8840 COMM BOARD monitoring time / CB t_monit
CU_S (COMM
BOARD, PROFINET)
Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [ms] 65535000 [ms] 20 [ms]
p8841[0...39] COMM BOARD send configuration data / CB S_config_data
CU_S (COMM
BOARD, PROFINET)
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 65535 0
p8842 COMM BOARD start configuration / CB config start
CU_S (COMM
BOARD, PROFINET)
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
p8848 IF2 PZD sampling time / IF2 PZD t_sample
CU_CX32, CU_S Can be changed: C1(3) Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1.00 [ms] 16.00 [ms] 4.00 [ms]
r8849[0...139] COMM BOARD receive configuration data / CB E_config_data
CU_S (COMM
BOARD, PROFINET)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r8850[0...4] CO: IF2 PZD receive word / IF2 PZD recv word
A_INF, B_INF,
S_INF
Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: 2491
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -