List of parameters
Parameters
1-111
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the unique code number of the power unit.
Note: r0200 = 0: No power unit found
For parallel circuit configurations, the parameter index is assigned to a power unit.
Description: Sets the actual code number from r0200 to acknowledge the power unit being used.
When commissioned for the first time, the code number is automatically transferred from r0200 into p0201.
Note: The parameter is used to identify when the drive is being commissioned for the first time.
The power unit commissioning can only be exited (p0201 = r0200), if the actual and acknowledged code numbers
are identical (p0010 = 2).
For parallel circuit configurations, the parameter index is assigned to a power unit.
Description: Displays the name of the CompactFlash card in the ASCII code.
r0203[0]: Name character 1
...
r0203[15]: Name character 16
For the commissioning software, the ASCII characters are displayed uncoded.
Notice: An ASCII table (excerpt) can be found, for example, in the following List Manual:
Description: Displays the type of power unit found.
Values: 2: MICROMASTER 440
3: MICROMASTER 411
4: MICROMASTER 410
5: MICROMASTER 436
r0200[0...n] Power unit, actual code number / PU code no. actual
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p0201[0...n] Power unit code number / PU code number
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed: C2(2) Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 65535 0
r0203[0...15] CompactFlash card name / CF name
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 4
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0203[0...n] Actual power unit type / PU actual type
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
2 300 -