List of parameters
Parameters
1-431
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the scaling for the upper torque limit.
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Note: This parameter can be freely interconnected.
The value has the above significance if it is interconnected from connector input p1528.
Description: Sets the scaling for the lower torque limit or the torque limit when regenerating.
Dependency: p1400 bit 4 = 0: Upper / lower
p1400 bit 4 = 1: Motoring / generating
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Note: This parameter can be freely interconnected.
The value has the above significance if it is interconnected from connector input p1528.
Description: Sets the scaling for the lower force limit or the force limit when regenerating.
Dependency: p1400 bit 4 = 0: Upper / lower
p1400 bit 4 = 1: Motoring / generating
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Note: This parameter can be freely interconnected.
The value has the above significance if it is interconnected from connector input p1528.
Description: Sets the scaling for the lower torque limit.
p1524[0...n] CO: Torque limit upper scaling / M_max upper scal
VECTOR (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5620, 5630,
6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
-2000.0 [%] 2000.0 [%] 100.0 [%]
p1525[0...n] CO: Torque limit lower/regenerating scaling / M_max low/gen scal
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5620, 5630,
6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
-2000.0 [%] 2000.0 [%] 100.0 [%]
p1525[0...n] CO: Force limit lower/regenerative scaling / F_max low/gen scal
SERVO (Lin) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5620, 5630,
6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
-2000.0 [%] 2000.0 [%] 100.0 [%]
p1525[0...n] CO: Torque limit lower scaling / M_max lower scal
VECTOR (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
-2000.0 [%] 2000.0 [%] 100.0 [%]