Siemens SINAMICS S Series - p1524[0...n] CO: Torque limit upper scaling; M_max upper scal; p1525[0...n] CO: Torque limit lower;regenerating scaling; M_max low;gen scal; p1525[0...n] CO: Force limit lower;regenerative scaling; F_max low;gen scal; p1525[0...n] CO: Torque limit lower scaling; M_max lower scal

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-431
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the scaling for the upper torque limit.
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Note: This parameter can be freely interconnected.
The value has the above significance if it is interconnected from connector input p1528.
Description: Sets the scaling for the lower torque limit or the torque limit when regenerating.
Dependency: p1400 bit 4 = 0: Upper / lower
p1400 bit 4 = 1: Motoring / generating
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Note: This parameter can be freely interconnected.
The value has the above significance if it is interconnected from connector input p1528.
Description: Sets the scaling for the lower force limit or the force limit when regenerating.
Dependency: p1400 bit 4 = 0: Upper / lower
p1400 bit 4 = 1: Motoring / generating
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Note: This parameter can be freely interconnected.
The value has the above significance if it is interconnected from connector input p1528.
Description: Sets the scaling for the lower torque limit.
p1524[0...n] CO: Torque limit upper scaling / M_max upper scal
VECTOR (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5620, 5630,
6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
-2000.0 [%] 2000.0 [%] 100.0 [%]
p1525[0...n] CO: Torque limit lower/regenerating scaling / M_max low/gen scal
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5620, 5630,
6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
-2000.0 [%] 2000.0 [%] 100.0 [%]
p1525[0...n] CO: Force limit lower/regenerative scaling / F_max low/gen scal
SERVO (Lin) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5620, 5630,
6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
-2000.0 [%] 2000.0 [%] 100.0 [%]
p1525[0...n] CO: Torque limit lower scaling / M_max lower scal
VECTOR (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
-2000.0 [%] 2000.0 [%] 100.0 [%]