Parameters
List of parameters
1-34
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Operating display for Terminal Module 15 (TM15).
Values: 0: [00] Module in cyclic operation
40: [40] Module not in cyclic operation
50: [50] Alarm
60: [60] Fault
70: [70] Initialization
120: [120] Module de-activated
250: [250] Device signals a topology error
Notice: For several missing enable signals, the corresponding value with the highest number is displayed.
Description: Operating display for Terminal Module 15 (TM15).
Values: 0: [00] Module in cyclic operation
40: [40] Module not in cyclic operation
50: [50] Alarm
60: [60] Fault
70: [70] Initialization
120: [120] Module de-activated
250: [250] Device signals a topology error
Notice: For several missing enable signals, the corresponding value with the highest number is displayed.
Description: Operating display for Terminal Module 54F (TM54F).
Values: 0: [00] Operation
10: [10] Ready
20: [20] Wait for run-up
31: [31] Commissioning software download active
33: [33] Remove topology error / acknowledge
34: [34] Exit the commissioning mode
35: [35] Carry out first commissioning
70: [70] Initialization
80: [80] Reset active
99: [99] Internal software error
Notice: For several missing enable signals, the corresponding value with the highest number is displayed.
r0002 TM15 operating display / TM15 op_display
TM15 Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 250 -
r0002 TM15DI/DO operating display / TM15D op_display
TM15DI_DO Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 250 -
r0002 TM54F operating display / TM54F op_display
TM54F_MA,
TM54F_SL
Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 99 -