List of parameters
Parameters
1-829
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the edge mode for digital input 16 ... 23 of terminal module 15 (TM15).
Assignment of the digital inputs to the bits:
DI 16: r4213.1 ... 0
DI 17: r4213.3 ... 2
DI 18: r4213.5 ... 4
DI 19: r4213.7 ... 6
DI 20: r4213.9 ... 8
DI 21: r4213.11 ... 10
DI 22: r4213.13 ... 12
DI 23: r4213.15 ... 14
Possible edge modes:
Bit x, y = 0, 0 --> no edge detection
Bit x, y = 0, 1 --> rising - rising edge
Bit x, y = 1, 0 --> falling - falling edge
Bit x, y = 1, 1 --> rising - falling edge or falling - rising edge
Note: DI: Digital input
Description: Sets the enable signal with bits 0 ... 5 for DI/DO 0 ... 5 of terminal module 17 (TM17).
Sets the triggering of the enable signal with bits 8 ... 13.
The following assignment applies:
Enable signal for DI/DO 0, 1, 2, 3, 4 or 5 via DI/DO 10, 11, 12, 13, 14 or 15.
Note: DI/DO: Bidirectional Digital Input/Output
r4213 TM15 edge mode digital input 16 ... 23 / TM15 EdgMd DI16-23
TM15 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p4220 TM17 enable DI/DO 0 ... 5 / TM17 enable 0-5
TM17 Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI/DO 0 (X520.2) With enable Without enable -
01 DI/DO 1 (X520.3) With enable Without enable -
02 DI/DO 2 (X520.5) With enable Without enable -
03 DI/DO 3 (X520.6) With enable Without enable -
04 DI/DO 4 (X520.8) With enable Without enable -
05 DI/DO 5 (X520.9) With enable Without enable -
08 DI/DO 10 (X522.2) Level-triggered Edge-triggered -
09 DI/DO 11 (X522.3) Level-triggered Edge-triggered -
10 DI/DO 12 (X522.5) Level-triggered Edge-triggered -
11 DI/DO 13 (X522.6) Level-triggered Edge-triggered -
12 DI/DO 14 (X522.8) Level-triggered Edge-triggered -
13 DI/DO 15 (X522.9) Level-triggered Edge-triggered -