Siemens SINAMICS S Series - p1703[0...n] Isq current controller pre-control scaling; Isq_ctr_prectrScal; p1704[0...n] EMF scaling of the Isq current controller pre-control; EMF scal Isq_ctrl; p1705[0...n] Flux setpoint;actual value tracking threshold; Flux track thresh; p1715[0...n] Current controller P gain; I_ctrl Kp

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-468
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the scaling of the dynamic current controller pre-control for the torque/force-generating current component Isq.
Description: Sets the scaling of the EMF pre-control for the Isq current controller.
Description: Threshold for the setpoint - actual value tracking of the EMF pre-control of the Isq current controller.
Description: Sets the proportional gain of the current controller for the lower adaptation current range. This value is automatically
preset using p3900 or p0340 when commissioning has been completed.
Dependency: p0391, p0392 and p0393 are only available for SERVO.
Refer to: p0391, p0392, p0393
Note: For p0393 = 100 %, the current controller adaptation is disabled and p1715 is effective over the entire range.
Description: Sets the proportional gain of the current controller for the lower adaptation current range. This value is automatically
preset using p3900 or p0340 when commissioning has been completed.
p1703[0...n] Isq current controller pre-control scaling / Isq_ctr_prectrScal
VECTOR (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 4
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 6714
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.0 [%] 200.0 [%] 70.0 [%]
p1704[0...n] EMF scaling of the Isq current controller pre-control / EMF scal Isq_ctrl
VECTOR (n/M) Can be changed: U, T Calculated: - Access level: 4
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
0.0 [%] 200.0 [%] 100.0 [%]
p1705[0...n] Flux setpoint/actual value tracking threshold / Flux track thresh
VECTOR (n/M) Can be changed: U, T Calculated: - Access level: 4
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 100.0 [%]
p1715[0...n] Current controller P gain / I_ctrl Kp
SERVO Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5714, 6714
P-Group: Closed-loop control Units group: 18_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.000 [V/A] 100000.000 [V/A] 0.000 [V/A]
p1715[0...n] Current controller P gain / I_ctrl Kp
VECTOR (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5714, 6714
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.000 100000.000 0.000