Parameters
List of parameters
1-52
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
- actual torque limit = M_max offset - M_max lower effective (r1539)
For the actual torque limit = 0, the following applies: r0033 = 100 %
For the actual torque limit < 0, the following applies: r0033 = 0 %
Description: Displays the smoothed torque/force utilization as a percentage.
The torque/force utilization is obtained from the required smoothed torque/force referred to the torque/force limit.
Note: Smoothing time constant = 100 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The force utilization is available smoothed (r0033) and unsmoothed (r0081).
For F_set total (r0079) > F_max offset (p1532), the following applies:
- demanded torque = F_set total - F_max offset
- actual force limit = F_max upper effective (r1538) - F_max offset
For F_set total (r0079) <= F_max offset (p1532), the following applies:
- demanded force = F_max offset - F_set total
- actual force limit = F_max offset - F_max lower effective (r1539)
For the actual force limit = 0, the following applies: r0033 = 100 %
For the actual force limit < 0, the following applies: r0033 = 0 %
Description: Displays the temperature currently measured at X21 (booksize) or X41 (chassis).
When using an Active Interface Module (p0220 = 41 ... 45) a bimetallic sensor must be connected-up to monitoring
the temperature. The temperature sensor type is indicated using p0601 and cannot be changed when an Active
Interface Module is being used.
Temperature within permissible limit values: r0035 = -50°C
Temperature outside the permissible limit values: r0035 = -250°C
Dependency: Refer to: A06260, F06261, F06262
Notice: The function in r0192.11 must be available in order to obtain a correct display.
Note: For r0035 equal to -200.0 °C, the following applies:
- "no sensor available" selected in p0601!
For r0035 equal to -300.0 °C, the following applies:
- a KTY84 is selected in p0601 but is not connected!
- the temperature display is not valid (temperature sensor error)!
r0033 Force utilization smoothed / F_util smooth
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 8012
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r0035 CO: Temperature input / Temp input
A_INF, S_INF Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: 21_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]