List of parameters
Parameters
1-399
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: In the standard state (the reference model is de-activated), r1438 = r1439.
Description: Displays the speed setpoint after setpoint limiting for the P component of the velocity controller.
For V/f operation, the value that is displayed is of no relevance.
Dependency: Refer to: r1439
Note: In the standard state (the reference model is de-activated), r1438 = r1439.
Description: Displays the speed setpoint for the I component of the speed controller (output of the reference model after the set-
point limiting).
Dependency: Refer to: r1438
Note: In the standard state (the reference model is de-activated), r1438 = r1439.
Description: Displays the velocity setpoint for the I component of the velocity controller (output of the reference model after the
setpoint limiting).
Dependency: Refer to: r1438
Note: In the standard state (the reference model is de-activated), r1438 = r1439.
Description: Sets the smoothing time constant (PT1) for the speed actual value.
Dependency: Refer to: r0063
r1438 CO: Velocity controller, velocity setpoint / v_ctrl v_set
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1550, 1590,
5030, 5040, 5042, 5210, 5300,
5620
P-Group: Closed-loop control Units group: 4_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
r1439 Speed setpoint, I component / n_set I_comp
SERVO, VECTOR
(n/M)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5030, 5040,
6031
P-Group: Closed-loop control Units group: 3_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r1439 Velocity setpoint, I component / v_set I_comp
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5030, 5040,
6031
P-Group: Closed-loop control Units group: 4_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
p1441[0...n] Actual speed smoothing time / n_ist T_smooth
SERVO Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 4710, 4715
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [ms] 50.00 [ms] 0.00 [ms]