Siemens SINAMICS S Series - p2628 BI: EPOS traversing block selection, bit 3; Trav_blk sel bit 3; p2629 BI: EPOS traversing block selection, bit 4; Trav_blk sel bit 4; p2630 BI: EPOS traversing block selection, bit 5; Trav_blk sel bit 5; p2631 BI: EPOS activate traversing task (0 -> 1); Trav_task act

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-660
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source to select the traversing block, bit 3.
Dependency: Binector inputs p2625, p2626, p2627, p2628, p2629 and p2630 are used to select one of the maximum of 64 tra-
versing blocks.
Refer to: p2625, p2626, p2627, p2629, p2630
Description: Sets the signal source to select the traversing block, bit 4.
Dependency: Binector inputs p2625, p2626, p2627, p2628, p2629 and p2630 are used to select one of the maximum of 64 tra-
versing blocks.
Refer to: p2625, p2626, p2627, p2628, p2630
Description: Sets the signal source to select the traversing block, bit 5.
Dependency: Binector inputs p2625, p2626, p2627, p2628, p2629 and p2630 are used to select one of the maximum of 64 tra-
versing blocks.
Refer to: p2625, p2626, p2627, p2628, p2629
Description: Sets the signal source for "activating traversing task".
BI: p2631 = 0/1 signal
The traversing task, selected using BI: p2625 ... p2630, is started.
Dependency: Refer to: p2625, p2626, p2627, p2628, p2629, p2630, p2640, p2641
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2628 BI: EPOS traversing block selection, bit 3 / Trav_blk sel bit 3
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3640
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2629 BI: EPOS traversing block selection, bit 4 / Trav_blk sel bit 4
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3640
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2630 BI: EPOS traversing block selection, bit 5 / Trav_blk sel bit 5
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3640
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2631 BI: EPOS activate traversing task (0 -> 1) / Trav_task act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3640
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0