List of parameters
Parameters
1-685
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
[5] = Fixed value +100 %
[6] = Fixed value +150 %
[7] = Fixed value +200 %
[8] = Fixed value -5 %
[9] = Fixed value -10 %
[10] = Fixed value -20 %
[11] = Fixed value -50 %
[12] = Fixed value -100 %
[13] = Fixed value -150 %
[14] = Fixed value -200 %
Dependency: Refer to: p2900, p2901, p2930
Note: The signal sources can, for example, be used to interconnect scalings.
Description: Sets a fixed value for torque.
Dependency: Refer to: p2900, p2901
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Note: The value can, for example, be used to interconnect a supplementary torque.
Description: Sets a fixed value for force.
Dependency: Refer to: p2900, p2901
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Note: The value can, for example, be used to interconnect a supplementary force.
Description: Torque constant of the synchronous motor measured by the motor identification.
Dependency: Refer to: r0334, r1937
Note: This parameter is not used for induction motors (p0300 = 1xx).
p2930[0...n] CO: Fixed value M [Nm] / Fixed value M [Nm]
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 1021
P-Group: Free function blocks Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-100000.00 [Nm] 100000.00 [Nm] 0.00 [Nm]
p2930[0...n] CO: Fixed value F [N] / Fixed value F [N]
SERVO (Lin) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 1021
P-Group: Free function blocks Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-100000.00 [N] 100000.00 [N] 0.00 [N]
p3016 Motor identification - torque constant / MotId kT
SERVO Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: 28_1 Unit selection: p0100
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
0.00 [Nm/A] 100.00 [Nm/A] 0.00 [Nm/A]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S Series and is the answer not in the manual?

Siemens SINAMICS S Series Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals