Description: Sets the speed to change over the motor model for operation with encoder.
Dependency: Refer to: p1756
Note: Induction motor (ASM):
The motor model is influenced for speeds/velocities greater than p1752.
Synchronous motor (SRM):
A monitoring (F07412) is activated for speeds/velocities greater than p1752.
The motor model is additionally influenced when kT adaptation is activated (p1780.3 = 1).
Description: Sets the velocity to change over the motor model for operation with encoder.
Dependency: Refer to: p1756
Note: Induction motor (ASM):
The motor model is influenced for speeds/velocities greater than p1752.
Synchronous motor (SRM):
A monitoring (F07412) is activated for speeds/velocities greater than p1752.
The motor model is additionally influenced when kT adaptation is activated (p1780.3 = 1).
Bit field: Bit Signal name 1 signal 0 signal FP
00 Controlled operation Active Inactive -
01 Set ramp-function generator Active Inactive -
02 Stop RsLh adaptation Yes No -
03 Feedback Active Inactive -
04 Encoder operation Active Inactive -
05 Holding angle Yes No -
06 Acceleration criteria Active Inactive -
07 Set angular integrator PEM No Yes -
08 Stop Kt adaptation PEM No Yes -
09 PolID active PEM SLVC No Yes -
10 I injection PEM No Yes -
11 Speed controller output cannot be set to
zero
Yes No -
12 Rs adapt waits Yes No -
13 Motor operation Yes No -
14 Stator frequency sign Positive Negative -
15 Torque sign Motor mode Regenerative mode -
p1752[0...n] Motor model changeover speed operation with encoder / MotMod n_chgov enc
SERVO Can be changed: U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: 3_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.0 [RPM] 210000.0 [RPM] 210000.0 [RPM]
p1752[0...n] Motor model with encoder changeover velocity / MotMod v_chgov enc
SERVO (Lin) Can be changed: U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: 4_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.0 [m/min] 1000.0 [m/min] 1000.0 [m/min]