Siemens SINAMICS S Series - r1436 CO: Speed controller reference model speed setpoint output; RefMod n_set outp; r1436 CO: Velocity controller, reference model velocity_setpoint output; RefMod v_set outp; p1437[0...n] CI: Speed controller, reference model I component input; n_ctrRefMod I_comp; r1438 CO: Speed controller, speed setpoint; n_ctrl n_set

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-398
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Together with p1433 and p1434, the characteristics (in the time domain) of the P-controlled velocity control loop
can be emulated.
Refer to: p0115, p1433, p1434
Description: Displays the speed setpoint at the output of the reference model.
Dependency: For VECTOR (r0107) the following applies:
The reference model is activated with p1400.3 = 1.
Description: Displays the velocity setpoint at the output of the reference model.
Dependency: For VECTOR (r0107) the following applies:
The reference model is activated with p1400.3 = 1.
Description: Sets the signal source for speed setpoint for the integral component of the speed controller.
Dependency: The reference model is activated with p1400.3 = 1.
Refer to: p1400
Caution: In should be ensured that a speed setpoint is selected as signal source that corresponds to the setpoint for the P
component of the speed controller.
Description: Displays the speed setpoint after setpoint limiting for the P component of the speed controller.
For V/f operation, the value that is displayed is of no relevance.
Dependency: Refer to: r1439
r1436 CO: Speed controller reference model speed setpoint output / RefMod n_set outp
SERVO, VECTOR
(n/M)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5030, 6031
P-Group: Closed-loop control Units group: 3_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r1436 CO: Velocity controller, reference model velocity_setpoint output /
RefMod v_set outp
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5030, 6031
P-Group: Closed-loop control Units group: 4_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
p1437[0...n] CI: Speed controller, reference model I component input / n_ctrRefMod I_comp
VECTOR (n/M) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6031
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1436[0]
r1438 CO: Speed controller, speed setpoint / n_ctrl n_set
SERVO, VECTOR
(n/M)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1550, 1590,
1700, 5030, 5040, 5042, 5210,
5300, 5620, 6031, 6040
P-Group: Closed-loop control Units group: 3_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]