EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-16 1690 - Vector control, V;f control

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Overviews
2-1118
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-16 1690 – Vector control, V/f control
- 1690 -
Function diagram
87654321
fp_1690_01_eng.vsd
DO: VECTOR
SINAMICS S
30.03.07 V02.05.00
+
+
+
+
+
Flying restart mode
p1200
Vdc_ctrl config
p1280
Slip compensation
p1335
Uf Res_damp gain
p1338
+
Soft starting
p1350
Imax closed-loop
frequency control
p1340 ... p1341
Imax closed-loop
voltage control
p1345 ... p1346
Control mode
p1300
U_boost perm
p1310
U_boost accelerate
p1311
I_max reduction
[6310]
[6320]
[6310] [6310]
[3050.8]
[8016.8]
[6730.4]
[6714.5]
r0066
f_outp
U_outp smooth
r0025
I_outp max
r0067
I_max_ctrl f_outp
r1343
I_max_ctrl U_outp
r1344
U_output
r0072
[6730.4]
r0068
I_act abs.val.
r1170
n_ctrl setp sum
Speed actual value
calculation
[4715]
+
Mot PolePairNo act
r0313
60
[6300.8]
[6300]
f_set
100 ms
r1119
RFG setpt at input
Ramp-function
generator
[6030.1]
[3060]
I_max motor module
MIN
p0640
r0056
.
.
.
[2526]
Refer to [1020.7]
p0115[y] (Motor Modules)
Overviews - Vector control, V/f control
f_outp smooth
r0024
100 ms
r0094
Transformat_angle
r1359
Angle difference
Uf angle setpt
(0)
p1356
Sym act angle
p1358
+

Table of Contents

Related product manuals