EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-280 9880 - Analog inputs (AI 0... AI 3)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Voltage Sensing Module (VSM)
Function Diagrams
2-1415
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-280 9880 – Analog inputs (AI 0 ... AI 3)
- 9880 -
87654321
fp_9880_01_eng.vsd
DO: A_INF, S_INF, VECTOR
SINAMICS S
04.06.07 V02.05.00
Voltage Sensing Module (VSM) - Analog inputs (AI 0 ... AI 3)
X520.2
X520.1
Rated line freq
p0211
X520.4
X520.3
X521.1
X521.2
A
D
Rated line freq
p0211
Limit value
comparison
INF C_filter
p0221
A06250
“Defective
capacitor(s)
in at least
one phase
of line filter“
r3671
r3673
VSM input U_scaler
p3660
x
2
x
1
y
+/-10 V
r3672
r3674
VSM CT_gain
p3670
x
2
x
1
y
A
D
X522.1
X522.2
r3662
I
1
I
2
I
3
VSM CT_gain
p3670
x
2
x
1
y
r3661
U
3
U
2
U
1
A
D
U
3
f2
3I
3
C
3
U
2
f2
3I
2
C
2
U
1
f2
3I
1
C
1
+
-
AI 2
+
-
AI 3
X521.3
X522.3
f
VSMfilt C A_thresh
r3676
C
1
C
2
C
3
100 V
690 V
r3677[0]
r3677[1]
r3677[2]
PT1 smoothing
[8850.1]
[8950.1]
p0115[3] (2000.00 µs)
p0115[1] (250.00 µs)
+/-10 V
0.5 s
A
D
0.5 s
0.5 s
Rated line freq
p0211
PT1 smoothing
0.5 s
0.5 s
0.5 s
PT1 smoothing
PT1 smoothing
VSM input U_scaler
p3660
x
2
x
1
y
Function diagram
<1> Can only be used with the Chassis Active Line Modules.
<1>
[8850.1]
[8950.1]
+
-
AI 0
+
-
AI 1
<2> The VECTOR drive object is assigned a dynamic index (p0150).
<2>
<2>
<2>
<2>

Table of Contents