List of parameters
Parameters
1-553
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the PZD byte offset in the PROFIdrive send telegram (master output).
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
Note: IF1: Interface 1
Value range:
0 - 242: Byte offset
255: Not occupied
Description: Displays the PZD byte offset in the PROFIdrive send telegram (master output).
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
Note: IF1: Interface 1
Value range:
0 - 242: Byte offset
255: Not occupied
r2076[0...14] IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r2076[0...7] IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
A_INF, B_INF,
S_INF
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -