Siemens SINAMICS S Series - p9910 Transfer additional components into the target topology; Transfer comp; p9915 DRIVE-CLiQ data transfer error shutdown threshold master; DLQ fault master; p9916 DRIVE-CLiQ data transfer error shutdown threshold slave; DLQ fault slave; p9920[0...19] Licensing, enter license key; Enter license key

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-1044
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
For p9909 = 0, serial numbers and hardware versions are not automatically transferred. In this case, the transfer
must be made using p9904.
Dependency: Refer to: p9904, p9905
Note: The modified target topology is automatically saved in a non-volatile fashion when the drive object runs-up (e.g.
after a POWER ON).
Special case for Control Unit and option slot modules:
When replacing these components, independent of p9909, the serial number and hardware version are automati-
cally transferred and saved in a non-volatile fashion.
Description: Transfer additional inserted DRIVE-CLiQ components into the target topology and add the appropriate drive objects
to the project.
Values: 0: No selection
1: Drive object type SERVO
2: Drive object type VECTOR
3: SINAMICS GM (DFEMV & VECTORMV)
4: SINAMICS SM (AFEMV & VECTORMV)
5: SINAMICS GL (VECTORGL)
Description: Only for internal Siemens service.
Description: Only for internal Siemens service.
Description: Enters the license key for this drive unit.
Example of the license key:
EACZ-QBCA = 69 65 67 90 45 81 66 67 65 dec (ASCII characters)
p9910 Transfer additional components into the target topology / Transfer comp
CU_CX32, CU_S Can be changed: C1(1) Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 5 0
p9915 DRIVE-CLiQ data transfer error shutdown threshold master / DLQ fault master
CU_CX32, CU_S Can be changed: C1(1) Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex 0007 07FF hex 0007 02FF hex
p9916 DRIVE-CLiQ data transfer error shutdown threshold slave / DLQ fault slave
CU_CX32, CU_S Can be changed: C1(1) Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex 0007 07FF hex 0007 02FF hex
p9920[0...19] Licensing, enter license key / Enter license key
CU_S Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -