EasyManua.ls Logo

Siemens SINAMICS S Series - p0312[0...n] Rated motor torque; Mot M_rated; p0312[0...n] Rated motor force; Mot F_rated; r0313[0...n] Motor pole pair number, actual (or calculated); Mot PolePairNo act

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-138
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the rated motor torque (rating plate).
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note: The parameter is automatically preset for motors from the motor list (p0301).
Description: Sets the rated motor force (rating plate).
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note: The parameter is automatically preset for motors from the motor list (p0301).
Description: Displays the number of motor pole pairs. The value is used for internal calculations.
Values:
r0313 = 1: 2-pole motor
r0313 = 2: 4-pole motor
etc.
Dependency: For p0314 > 0, the entered value is displayed in r0313.
For p0314 = 0, the pole pair number (r0313) is automatically calculated from the rated frequency (p0310) and the
rated speed (p0311).
Refer to: p0310, p0311, p0314
Note: For the automatic calculation, the pole pair number is set to the value of 2 if the rated speed or the rated frequency
is zero.
p0312[0...n] Rated motor torque / Mot M_rated
SERVO Can be changed: C2(3) Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 7_4 Unit selection: p0100
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
0.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]
p0312[0...n] Rated motor force / Mot F_rated
SERVO (Lin) Can be changed: C2(3) Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 8_4 Unit selection: p0100
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
0.00 [N] 1000000.00 [N] 0.00 [N]
r0313[0...n] Motor pole pair number, actual (or calculated) / Mot PolePairNo act
SERVO Can be changed: - Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: MDS, p0130 Func. diagram: 5300
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -

Table of Contents