Siemens SINAMICS S Series - r1548[0...1] CO: Stall current limit torque-generating maximum; Isq_max stall; r1549 CO: Stall power actual value; P_stall; p1550[0...n] BI: Transfer actual torque as torque offset; Accept act torque; p1550[0...n] BI: Transfer actual force as force offset; Accept act force

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-443
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the limit for the torque-generating current component using the stall calculation, the current limit of the
Motor Module as well as the parameterization in p0640.
Index: [0] = Upper limit
[1] = Lower limit
Description: Displays the instantaneous stall power.
Dependency: Refer to: p0326
Description: For a positive edge, the actual torque (r0079[0]) at this instant in time is used instead of the torque offset from
p1532 as long as p1550 remains at 1.
Description: For a positive edge, the actual force (r0079[0]) at this instant in time is used instead of the force offset from p1532
as long as p1550 remains at 1.
r1548[0...1] CO: Stall current limit torque-generating maximum / Isq_max stall
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1549 CO: Stall power actual value / P_stall
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: 14_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [kW] - [kW] - [kW]
p1550[0...n] BI: Transfer actual torque as torque offset / Accept act torque
SERVO Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 9718.23
p1550[0...n] BI: Transfer actual force as force offset / Accept act force
SERVO (Lin) Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 9718.23