EasyManua.ls Logo

Siemens SINAMICS S Series - r7871[0...9] Configuration changes drive object; Config_chng DO

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-920
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
[7] = Activate/de-activate component
[8] = Reference or changeover parameters (e.g. p2000)
[9] = Parameter count through Drive Control Chart (DCC)
Dependency: Refer to: r7868, r7870
Description: Displays the configuration changes on the drive object.
Index 0:
When changing one of the following indices, then the value in this index is incremented.
Index 1:
Drive object configuration. When changing p10, p0107 or p108, the value in this index is incremented.
Index 2:
Drive object name. When changing p0199, the value in this index is incremented.
Index 3:
Drive object structure. When changing a parameter that is relevant for the structure (e.g. number of data sets), the
value in this index is incremented.
Index 4:
Drive object BICO interconnections. When changing r3977, the value in this index is incremented.
Index 6:
Drive object, data save.
0: There are not parameter changes to save.
1: There are parameter changes to save.
Index 8:
Drive object changeover of units. When changing reference or changeover parameters (e.g. p2000, p0304 ...), the
value in this index is incremented.
Index 9:
Drive object parameter count. When changing the number of parameters by loading Drive Control Chart (DCC), the
value in this index is incremented.
Index: [0] = Sum of the following indices
[1] = p0010, r0107 or r0108
[2] = Drive object name (p0199)
[3] = Structure-relevant parameters (e.g. p0180)
[4] = BICO interconnections
[5] = Activate/de-activate drive object
[6] = Data back-up required
[7] = Reserved
[8] = Reference or changeover parameters (e.g. p2000)
[9] = Parameter count through Drive Control Chart (DCC)
Dependency: Refer to: r7868, r7870
r7871[0...9] Configuration changes drive object / Config_chng DO
CU_LINK, DMC20,
TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -

Table of Contents

Related product manuals