Siemens SINAMICS S Series - p0621[0...n] Temperature identification after restart; Temp_ident restart; p0622[0...n] Motor excitation time for temp_ident after powering-up again; t_excit temp_id; r0623 Stator resistance after temperature identification; R_stator temp_id; p0625[0...n] Motor ambient temperature; Mot T_ambient

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-214
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Configuration of the temperature identification after powering-up again. If the identification is selected, when power-
ing-up for the first time after the system run-up, the stator resistance is measured and from this the temperature
determined. The thermal model is then suitably initialized.
Values: 0: No temperature identification
1: Temperature identification after restart
2: Temperature identification after each power-up
Description: Sets the excitation time of the motor during the temperature identification after powering-up again (restart).
Description: Displays the identified stator resistance after the temperature identification run.
Description: Defines the ambient temperature of the motor to calculate the temperature model.
Note: The parameters for stator and rotor resistance (p0350, p0354) refer to this temperature.
Description: Defines the rated overtemperature of the stator core referred to the ambient temperature.
p0621[0...n] Temperature identification after restart / Temp_ident restart
VECTOR (n/M) Can be changed: C2(3), T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
0 2 0
p0622[0...n] Motor excitation time for temp_ident after powering-up again / t_excit temp_id
VECTOR (n/M) Can be changed: C2(3), U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
0.000 [s] 20.000 [s] 0.000 [s]
r0623 Stator resistance after temperature identification / R_stator temp_id
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
- [Ohm] - [Ohm] - [Ohm]
p0625[0...n] Motor ambient temperature / Mot T_ambient
SERVO, VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
-40 [°C] 80 [°C] 20 [°C]
p0626[0...n] Motor overtemperature, stator core / Mot T_over core
SERVO, VECTOR Can be changed: C2(3), U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: 21_2 Unit selection: p0505
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
20 [K] 200 [K] 50 [K]