Parameters
List of parameters
1-1046
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the status when checking the CompactFlash card after powering-up.
0: CompactFlash Card still not checked.
1: Check running.
2: Check successfully completed.
3: Check indicates an error.
Dependency: Refer to: r9925
Refer to: A01016
Description: Only for service purposes.
Index: [0] = System logbook stage (0: Not active)
[1] = COM2/COM1 (0: COM2, 1: COM1)
[2] = Activate file write (0: Not active)
[3] = Display time stamp (0: Not displayed)
[4] = Reserved
[5] = Reserved
[6] = Reserved
[7] = Reserved
[8] = System logbook file size (stages, each 10 kB)
Notice: Before powering-down the Control Unit, ensure that the system logbook is switched-out (p9930[0] = 0).
Description: Only for service purposes.
Description: Only for service purposes.
r9926 CompactFlash card check status / CF check status
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p9930[0...8] System logbook activation / SYSLOG activation
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 4
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 255 0
p9931[0...99] System logbook module selection / SYSLOG mod select.
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
p9932 Save system logbook EEPROM / SYSLOG EEPROM save
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 4
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 255 0