List of parameters
Parameters
1-927
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: p8500
Description: Displays the signals of the bitwise received data.
These signals were interconnected and transferred to another Control Unit via BI: p8501[0...15].
Dependency: Refer to: p8501
Description: Displays the signals of the wordwise received data (process signal).
This signal value is interconnected and transferred to another Control Unit via CI: p8502.
Dependency: Refer to: p8502
Description: Displays the signals of the wordwise received data (process signal).
This signal value is interconnected and transferred to another Control Unit via CI: p8503.
Dependency: Refer to: p8503
r8511.0...15 BO: Data transfer 1 receive bitwise / Trans 1 recv bit
CU_CX32, CU_LINK Can be changed: - Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Receive signal from BI: p8501 On Off -
01 Receive signal from BI: p8501 On Off -
02 Receive signal from BI: p8501 On Off -
03 Receive signal from BI: p8501 On Off -
04 Receive signal from BI: p8501 On Off -
05 Receive signal from BI: p8501 On Off -
06 Receive signal from BI: p8501 On Off -
07 Receive signal from BI: p8501 On Off -
08 Receive signal from BI: p8501 On Off -
09 Receive signal from BI: p8501 On Off -
10 Receive signal from BI: p8501 On Off -
11 Receive signal from BI: p8501 On Off -
12 Receive signal from BI: p8501 On Off -
13 Receive signal from BI: p8501 On Off -
14 Receive signal from BI: p8501 On Off -
15 Receive signal from BI: p8501 On Off -
r8512 CO: Data transfer 0 receive wordwise / Trans 0 recv word
CU_CX32, CU_LINK Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 2211
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r8513 CO: Data transfer 1 receive wordwise / Trans 1 recv word
CU_CX32, CU_LINK Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 2211
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -