Parameters
List of parameters
1-580
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Values: 1: Acknowledgement only using POWER ON
2: IMMEDIATE acknowledged after the fault cause has been removed
3: Acknowledgement only for PULSE INHIBIT
Dependency: Selects the faults and sets the required acknowledge mode realized under the same index
Refer to: p2126
Notice: It is not possible to re-parameterize the acknowledge mode of a fault in the following cases:
- if there is no existing fault number.
- the message type is not "fault" (F).
- when a fault is present.
Note: The acknowledge mode can only be changed for faults with the appropriate identification.
Example:
F12345 and acknowledge mode = POWER ON (IMMEDIATELY) --> The acknowledge mode can be changed from
POWER ON to IMMEDIATELY.
Description: Selects faults or alarms which can be used as trigger.
Dependency: Refer to: r2129
Description: Trigger signal for the selected faults and alarms
Dependency: If one of the faults or alarms selected in p2128[n] occurs, then the particular bit of this binector output is set.
Refer to: p2128
Note: CO: r2129 = 0 --> None of the selected messages has occurred.
CO: r2129 > 0 --> At least one of the selected messages has occurred.
p2128[0...15] Selecting fault/alarm code for trigger / Message trigger
All objects Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 1750, 8070
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 65535 0
r2129.0...15 CO/BO: Trigger word for faults and alarms / Trigger word
All objects Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 1530, 8070
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Trigger signal p2128[0] On Off -
01 Trigger signal p2128[1] On Off -
02 Trigger signal p2128[2] On Off -
03 Trigger signal p2128[3] On Off -
04 Trigger signal p2128[4] On Off -
05 Trigger signal p2128[5] On Off -
06 Trigger signal p2128[6] On Off -
07 Trigger signal p2128[7] On Off -
08 Trigger signal p2128[8] On Off -
09 Trigger signal p2128[9] On Off -
10 Trigger signal p2128[10] On Off -
11 Trigger signal p2128[11] On Off -
12 Trigger signal p2128[12] On Off -
13 Trigger signal p2128[13] On Off -
14 Trigger signal p2128[14] On Off -
15 Trigger signal p2128[15] On Off -