EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-276 9680 - Status word sequence control

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Terminal Module 41 (TM41)
Function Diagrams
2-1409
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-276 9680 – Status word sequence control
- 9680 -
Function diagram
87654321
fp_9680_51_eng.vsd
DO: TM41
SINAMICS
13.03.07 V02.05.00
Terminal Module 41 (TM41) - Status word, sequence control
11
12
13
14
15
r0899
ZSW seq_ctrl
<1> Process data is requested from the control system.
PROFIdrive-Bit
Bit Nr.
10
9
8
7
6
5
4
3
0
1
2
From the sequence control [9682]
From the sequence control [9682]
From the sequence control [9678.7]
From the sequence control [9682]
From the sequence control [9682]
From the sequence control [9678.7]
2000.00 µs
r0899.0
r0899.1
r0899.4
r0899.5
r0899.2
r0899.6
r0899.9
1 = Ready to run
1 = Ready to power-up
Status word sequence control
1 = Operation enabled
Reserved
1 = No coast down active (OFF2 inactive)
1 = No fast stop active (OFF3 inactive)
1 = Power-on inhibit active
Reserved
Reserved
1 = Control requested <1>
Reserved
Reserved
Reserved
1 = Zero mark enabled
1 = Interface encoder simulation enabled
1 = Tracks A/B enabled
Bit 9 = 1 --> ready to exchange process data
r0899.13
r0899.14
r0899.15From TM41 Impulse encoder simulation (HW)
r0899.8
From TM41 Impulse encoder simulation (HW)
From TM41 Impulse encoder simulation (HW)

Table of Contents

Related product manuals