Siemens SINAMICS S Series - p2576 EPOS modulo correction, modulo range; Modulo corr range; p2577 BI: EPOS modulo correction activation; Modulo corr act; p2578 CI: EPOS software limit switch minus signal source; SW limSw Min S_src; p2579 CI: EPOS software limit switch plus signal source; SW limSwPlus S_src

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-646
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the modulo range for axes with modulo correction.
Dependency: Refer to: p2577
Description: Sets the signal source to activate modulo correction.
Dependency: Refer to: p2576
Note: When the signal state changes at the binector input, this only becomes effective in the "ready to power-up" state.
Selecting modulo correction:
The actual position setpoint in the modulo range is corrected. The position actual value differs from the position set-
point by the following error and can also leave the modulo range.
De-selecting modulo correction:
It is based on the actual position actual value.
Description: Sets the signal source for the software limit switch minus.
Dependency: Refer to: p2579, p2580, p2581, p2582
Refer to: A07469, A07477, A07479, F07481
Notice: A change to the software limit switch becomes immediately effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note: The following applies for the setting of the software limit switch:
Software limit switch minus < software limit switch plus
Description: Sets the signal source for the software limit switch plus.
p2576 EPOS modulo correction, modulo range / Modulo corr range
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 3635
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1 [LU] 2147482647 [LU] 360000 [LU]
p2577 BI: EPOS modulo correction activation / Modulo corr act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3630, 3635
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2578 CI: EPOS software limit switch minus signal source / SW limSw Min S_src
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Integer32 Dynamic index: - Func. diagram: 3630
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 2580[0]
p2579 CI: EPOS software limit switch plus signal source / SW limSwPlus S_src
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Integer32 Dynamic index: - Func. diagram: 3630
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 2581[0]