List of parameters
Parameters
1-681
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: p0505, r0108.12
Refer to: p2003
Note: This parameter represents the numerical value of the reference quantity in the currently selected units and is only
available for interconnection with Drive Control Chart (DCC).
Description: Displays the actual reference quantity for forces.
All forces specified as relative value are referred to this reference quantity. The reference quantity in this parameter
corresponds to 100% or 4000 hex or 4000 0000 hex.
Dependency: p0505, r0108.12
Refer to: p2003
Note: This parameter represents the numerical value of the reference quantity in the currently selected units and is only
available for interconnection with Drive Control Chart (DCC).
If a BICO interconnection is established between different physical quantities, then the particular reference quanti-
ties are used as internal conversion factor.
Example:
The actual value of the total force (r0079[0]) is connected to a test socket (e.g. p0771[0]). The actual force is cycli-
cally converted into a percentage of the reference force (p2003) and output according to the parameterized scaling.
Description: Displays the actual reference quantity for power ratings.
All power ratings specified as relative value are referred to this reference quantity. The reference quantity in this
parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
Dependency: This value is calculated as voltage x current for the infeed and as torque x speed for closed-loop controls.
Refer to: r2004
Note: This parameter represents the numerical value of the reference quantity in the currently selected units and is only
available for interconnection with Drive Control Chart (DCC).
The reference power is calculated as follows:
- 2 * Pi * reference speed / 60 * reference torque (motor)
- reference voltage * reference current * root(3) (infeed)
Description: Displays the actual reference quantity for angle.
All angles specified as relative value are referred to this reference quantity. The reference quantity in this parameter
corresponds to 100% or 4000 hex or 4000 0000 hex.
r2703 CO: Reference force actual / Ref force act
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r2704 CO: Reference power actual / Ref power act
A_INF, B_INF,
SERVO, S_INF,
TM41, VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r2705 CO: Reference angle actual / Ref angle act
A_INF, B_INF,
SERVO, S_INF,
TM41, VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -