EasyManua.ls Logo

Siemens SINAMICS S Series - p2088[0...3] Invert binector-connector converter status word; Bin;con ZSW inv; r2089[0...3] CO: Send binector-connector converter status word; Bin;con ZSW send

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-562
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
[14] = Bit 14
[15] = Bit 15
Dependency: Refer to: p2088, r2089
Description: Setting to invert the individual binector inputs of the binector connector converter.
Index: [0] = Status word 1
[1] = Status word 2
[2] = Free status word 3
[3] = Free status word 4
Dependency: Refer to: p2080, p2081, p2082, p2083, r2089
Description: Connector output to interconnect the status words to a PZD send word.
Index: [0] = Status word 1
[1] = Status word 2
[2] = Free status word 3
[3] = Free status word 4
p2088[0...3] Invert binector-connector converter status word / Bin/con ZSW inv
A_INF, B_INF,
CU_CX32, CU_S,
SERVO, S_INF,
TB30, TM15DI_DO,
TM31, TM41, VEC-
TOR
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 2472
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Bit 0 Inverted Not inverted -
01 Bit 1 Inverted Not inverted -
02 Bit 2 Inverted Not inverted -
03 Bit 3 Inverted Not inverted -
04 Bit 4 Inverted Not inverted -
05 Bit 5 Inverted Not inverted -
06 Bit 6 Inverted Not inverted -
07 Bit 7 Inverted Not inverted -
08 Bit 8 Inverted Not inverted -
09 Bit 9 Inverted Not inverted -
10 Bit 10 Inverted Not inverted -
11 Bit 11 Inverted Not inverted -
12 Bit 12 Inverted Not inverted -
13 Bit 13 Inverted Not inverted -
14 Bit 14 Inverted Not inverted -
15 Bit 15 Inverted Not inverted -
r2089[0...3] CO: Send binector-connector converter status word / Bin/con ZSW send
A_INF, B_INF,
CU_CX32, CU_S,
SERVO, S_INF,
TB30, TM15DI_DO,
TM31, TM41, VEC-
TOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 2472
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Bit 0 On Off -
01 Bit 1 On Off -
02 Bit 2 On Off -
03 Bit 3 On Off -
04 Bit 4 On Off -
05 Bit 5 On Off -
06 Bit 6 On Off -

Table of Contents