EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-95 2707 - Extended braking control; open;close brake (r0108.14 = 1)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Braking control
2-1206
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-95 2707 – Extended braking control / open/close brake (r0108.14 = 1)
- 2707 -
Function diagram
87654321
fp_2707_01_eng.vsd
DO: SERVO, VECTOR
SINAMICS S
23.02.07 V02.05.00
Braking control - Extended braking control, open/close brake (r0108.14 = 1)
<1> Motor holding brake configuration
0 = No brake or brake always applied (brake connected to the power unit)
1 = Brake control active (brake connected to the power unit)
2 = Brake always released (brake connected to the power unit)
3 = Brake control active (brake connection can be interconnected using BICO)
Note:
A motor brake cannot be connected to all power units. p1215 is set to 3 and the brake is controlled via a digital output (e.g. TM31).
<3> These blocks/modules are evaluated with the same sampling rate as the brake control and therefore may only be used to individually adapt the brake control.
<4> If the brake is permanently applied or released (p0855, p0858 or p1215), the drive does not wait until the brake is released or applied.
Brake OR
logic operation
result
1229.10
(0)
p1279[3]
Brake AND
logic operation
result
1229.11
<3>
Background
Refer to [1020.7]
<2> Priority assignment (high -> low): p1215, p0858, p0855, p0856/p1219, apply brake from standstill detection, p1218.
Magnetizing completed
r0056.4
T0
0.000...300.000 s
p1277(0.000)
Brake open threshold
(1)
p1220
(1)
Open brake
p1218[0]
0
1
Brake open threshold
0.00...200.00%
p1221(0.00)
Open brake (internal)
Brake threshold
exceeded
r1229.6
(1)
p1218[1]
[2711.1]
<2>
p1215 = 2
<1>
[2501.7]
p0855 1 = Unconditionally open the holding brake
r0898.7
[2501.7]
p0856
1 = Enable speed controller
r0898.12
(0)
p1219[2]
(r1229.9)
p1219[3]
Close brake (internal)
(0)
p1219[1]
(0)
Immediately close brake
p1219[0]
1
0
1
p1275.00 (0)
1
0
1
p1275.01 (0)
Request, pulse enable missing/n_ctrl inhibited
r1229.9
1
&
Request pulse enable
[2711.1]
[2711.8]
[2704.8]
Close brake from standstill detection
<1>
p1215 = 0
<2>
(0)
OR logic operation
p1279[0]
(0)
p1279[1]
(0)
AND logic operation
p1279[2]
[2501.7]
p0858
1 = Unconditionally close the holding brake
r0898.14
<4>
[2526.6]

Table of Contents