EasyManua.ls Logo

Siemens SINAMICS S Series - r2076[0...18] IF1 PROFIdrive diagnostics telegram offset PZD send; IF1 diag offs send; r2076[0...31] IF1 PROFIdrive diagnostics telegram offset PZD send; IF1 diag offs send

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-554
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the PZD byte offset in the PROFIdrive send telegram (master output).
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
[15] = PZD 16
[16] = PZD 17
[17] = PZD 18
[18] = PZD 19
Note: IF1: Interface 1
Value range:
0 - 242: Byte offset
255: Not occupied
Description: Displays the PZD byte offset in the PROFIdrive send telegram (master output).
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
[15] = PZD 16
[16] = PZD 17
r2076[0...18] IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
SERVO, TM41 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r2076[0...31] IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -

Table of Contents

Related product manuals