EasyManua.ls Logo

Siemens SINAMICS S Series - p3871 BI: Set long stator signal source commutation angle (p3872); Set S_src com_ang; p3872 CI: Long stator signal source commutation angle; S_src com_angle; p3873 BI: Long stator sig. source changeover to cl.-loop ctrl w; enc.; S_src ctrl w; enc

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-762
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Notice: The following restrictions apply to this function:
- it is not permissible to change over the drive data set.
- the encoder/drive may not be parked using a PROFIBUS telegram.
- a maximum of 4 drives may be connected to the Control Unit.
- it is not permissible to commutate with the zero mark (p0404).
Note: Re bit 00:
All of the help functions for long stator motors can be enabled/disabled using this bit.
Re bit 01:
When the bit is set, bit 14 (parking encoder active) is set to 0 in the encoder status word GX_ZSW independent of
whether the encoder is parked or not.
Description: Sets the signal source to set the commutation angle from CI: p3872.
Dependency: Refer to: p3870, p3872, p3873, p3874, r3875, p3876, p3878, p3879
Danger: If an incorrect commutation angle is set, this can result in instability in the closed-loop control and in turn injure per-
sonnel or cause damage to the machine !
Note: Setting takes place for a 0/1 signal edge.
Description: Sets the signal source for the commutation angle.
This angle is set for a 0/1 signal edge via BI: p3871.
Dependency: Refer to: p3870, p3871, p3873, r3875, p3876, p3878, p3879
Danger: If an incorrect commutation angle is set, this can result in instability in the closed-loop control and in turn injure per-
sonnel or cause damage to the machine !
Description: Sets the signal source to change over to closed-loop control with encoder.
Dependency: Refer to: p3870, p3871, p3872, p3874, r3875, p3876, p3878, p3879
Danger: If an incorrect commutation angle is set, this can result in instability in the closed-loop control and in turn injure per-
sonnel or cause damage to the machine !
p3871 BI: Set long stator signal source commutation angle (p3872) / Set S_src com_ang
SERVO Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p3872 CI: Long stator signal source commutation angle / S_src com_angle
SERVO Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 3878[0]
p3873 BI: Long stator sig. source changeover to cl.-loop ctrl w/ enc. / S_src ctrl w/ enc
SERVO Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: -
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0

Table of Contents

Related product manuals