Parameters
List of parameters
1-224
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the status word for the function "central measuring probe evaluation".
Description: Runs the appropriate ACX file on the CompactFlash card.
The binector inputs (BI) of the appropriate Command Data Set (CDS) are appropriately interconnected.
The selected ACX file must be located in the following directory:
... /PMACROS/<drive object>/P700/PMxxxxxx.ACX
Example:
p0700 = 6 --> the file PM000006.ACX is run.
Dependency: The ACX file to be run must be created according to the definition for ACX macros and must be saved in the direc-
tory intended on the CompactFlash card.
Refer to: p0015, p1000, p1500, r8571
Notice: No errors were issued during fast commissioning (p3900 = 1) when writing to parameters of the QUICK_IBN group!
Note: The macros in the specified directory are displayed in r8571. r8571 is not in the Expert list of the commissioning
software.
Macros available as standard are described in the technical documentation of the particular product.
BI: Binector input
r0688 CO: Central measuring probe, status word display / Cen meas ZSW disp
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Digital input, measuring probe 1 High Low -
01 Digital input, measuring probe 2 High Low -
02 Digital input, measuring probe 3 High Low -
03 Digital input, measuring probe 4 High Low -
04 Digital input, measuring probe 5 High Low -
05 Digital input, measuring probe 6 High Low -
08 Sub-sampling, measuring probe 1 High Low -
09 Sub-sampling, measuring probe 2 High Low -
10 Sub-sampling, measuring probe 3 High Low -
11 Sub-sampling, measuring probe 4 High Low -
12 Sub-sampling, measuring probe 5 High Low -
13 Sub-sampling, measuring probe 6 High Low -
p0700[0...n] Macro Binector Input (BI) / Macro BI
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed: C2(1), T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: CDS, p0170 Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 999999 0