Description: Sets the test of the feedback line for forced checking procedure.
Note: F-DO: Failsafe Digital Output
Description: Displays the single-channel status of the safety digital inputs F-DI 0 .. 9 at Terminal Module 54F (TM54F).
If a safety function is assigned to an input (e.g. via p10022), then the following applies:
- logical "0": The safety function is selected
- logical "1": The safety function is canceled
The interrelationship between the logical level and the external voltage level at the input depends on the parameter-
ization (refer to p10040) of the input as either NC or NO contact and is aligned to the use of a safety function:
With 24 V at the input, NC contacts have a logical "1" level, for 0 V at the input, a logical "0" level.
This means that an NC/NC contact parameterization of 0 V at both inputs of the F-DI selects the safety function, for
24 V at both inputs, deselects the safety function.
With 24 V at the input, NO contacts have a logical "0" level, for 0 V at the input, a logical "1" level.
This means that for an NC/NO contact parameterization, the level 0 V/24 V selects the safety function, the level 24
V/0 V deselects the safety function.
Note: F-DI: Failsafe Digital Input
p10046 SI test sensor feedback signal input DI 20 ... 23 / SI test sens FS
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 2848
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Read back F-DO 0 in DI 20 Test active No test -
01 Read back F-DO 1 in DI 21 Test active No test -
02 Read back F-DO 2 in DI 22 Test active No test -
03 Read back F-DO 3 in DI 23 Test active No test -
r10051.0...9 CO/BO: SI digital inputs status / SI DI status
TM54F_MA,
TM54F_SL
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 F-DI 0 Logical 1 Logical 0 2850
01 F-DI 1 Logical 1 Logical 0 2850
02 F-DI 2 Logical 1 Logical 0 2850
03 F-DI 3 Logical 1 Logical 0 2850
04 F-DI 4 Logical 1 Logical 0 2850
05 F-DI 5 Logical 1 Logical 0 2851
06 F-DI 6 Logical 1 Logical 0 2851
07 F-DI 7 Logical 1 Logical 0 2851
08 F-DI 8 Logical 1 Logical 0 2851
09 F-DI 9 Logical 1 Logical 0 2851