Parameters
List of parameters
1-476
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the hysteresis for the changeover speed of the motor model for sensorless operation.
Dependency: Refer to: p1755
Note: The parameter value refers to p1755.
Description: Sets the gain of the transient response controller when the motor model changes over from open-loop controlled
operation to closed-loop controlled operation.
Note: Only for ASM and PSM in sensorless operation:
The settling range starts at 0.5 * p1755 * p1756.
For ASM it ends at p1755 * p1756 or at p1755, if p1759 is at the maximum value.
For PSM it always ends at p1755 * p1756.
Description: Sets the minimum time for falling below the changeover speed when changing from closed-loop controlled opera-
tion to open-loop controlled operation.
Dependency: Refer to: p1755, p1756
Description: Sets the minimum time for exceeding the changeover speed when changing from open-loop controlled operation to
closed-loop controlled operation.
Dependency: Refer to: p1755, p1756
p1756 Motor model changeover speed hysteresis sensorless operation /
MotMod n_chgov hys
VECTOR Can be changed: U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.0 [%] 95.0 [%] 50.0 [%]
p1757[0...n] Motor model w/o enc. op./cl.-loop controlled stab. controller Kp / MotMod w/o enc Kp
VECTOR (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 4
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL, FEM Expert list: 1
Min Max Factory setting
0.01 10.00 0.70
p1758[0...n] Motor model changeover delay time closed/open-loop control / MotMod t cl_op
VECTOR (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
100 [ms] 10000 [ms] 1000 [ms]
p1759[0...n] Motor model changeover delay time open/closed loop control / MotMod t op_cl
VECTOR (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
0 [ms] 2000 [ms] 0 [ms]